Container Closure System
What container closure system is used to pack and store the drug substance?
The API goes into double low-density polyethylene bags of pharmaceutical grade. Both bags are sealed, then placed in an aluminum tin and the tin is sealed. Pack size is 1.0 kg per tin.
The choice of packaging reflects what this product actually needs. Triamcinolone acetonide is practically insoluble in water, but it is still dried to a loss-on-drying limit of 1.5%, and the packaging has to keep it that way until the customer opens the tin. Two sealed polyethylene bags give double protection against moisture ingress, and polyethylene itself does not react with the steroid. The aluminum tin serves a different purpose: it takes the knocks. Bags alone can be punctured or compressed during warehouse handling and transport, and a torn inner bag would expose the API to ambient humidity for the rest of its shelf life. The tin removes that risk, and its own seal closes the pack completely.
Stability
Which stability studies support the retest period and storage conditions?
Three batches were placed on stability under accelerated conditions (40 ± 2 °C / 75 ± 5% RH) and long-term conditions (25 ± 2 °C / 60 ± 5% RH), in line with the ICH Q1A design. Samples are pulled at the protocol intervals and tested against the release specification - description, identification, specific rotation, related substances, loss on drying, residual solvents and assay. Testing the same parameters each time means any drift in quality appears early, as a trend across time points, instead of surfacing only when the study ends. The results support the production, storage and packaging conditions described above and form the basis for setting the retest period.
Tianjin Pacific Chemical & Pharmaceutical Co., Ltd. commits to the following ongoing stability programme:
Accelerated and long-term testing of the three registration batches in accordance with the approved stability protocol.
Once routine commercial production begins, one batch each year will be added to the long-term study. This keeps the data behind the retest period current and representative of how the process actually runs in commercial operation.
If any abnormality is observed in a stability sample, the cause will be investigated and the relevant drug regulatory authority notified promptly. The affected batch is held back from release until the evaluation is complete.